Testing radon mitigation techniques in a pilot house from Baita-Stei radon prone area (Romania)

Abstract: This work presents the implementation and testing of several radon mitigation techniques in a pilot house in the radon prone area of Baita-Stei in NW part of Romania. Radon diagnostic investigations in the pilot house showed that the main source of radon was the building sub-soil and the soil near the house. The applied techniques were based on the depressurization and pressurization of the building sub-soil, on the combination of the soil depressurization system by an electric and an eolian fans. Also, there was made an application of a radon barrier membrane and a testing by the combination of the radon membrane by the soil depressurization system. Finally, the better obtained remedial efficiency was about 85%.

 Fuente: Journal of Environmental Radioactivity, Volume 140, February 2015, Pages 141–147

Editorial: Elsevier

 Fecha de publicación: 01/02/2015

Nº de páginas: 7

Tipo de publicación: Artículo de Revista

 DOI: 10.1016/j.jenvrad.2014.11.007

ISSN: 0265-931X,1879-1700

Url de la publicación: http://www.sciencedirect.com/science/article/pii/S0265931X14003270?np=y

Autoría

COSMA, CONSTANTIN

PAPP, BOTOND

CUCOS¸ (DINU), ALEXANDRA