Buscar

Estamos realizando la búsqueda. Por favor, espere...

Detalle_Publicacion

Use of the plasma RMS signal for on-line welding quality monitoring

Abstract: In this paper a new spectroscopic monitoring parameter is proposed for the on-line monitoring of welding processes, the plasma RMS signal, which is determined by considering the contribution from the spectral samples over a particular spectral window. This parameter is directly related to the heat input that can be estimated by measuring both welding voltage and current, but it exhibits a higher sensitivity to the appearance of weld defects. A comparison between the results obtained from the different spectroscopic parameters will be presented, with data from both experimental and field arc-welding tests.

Otras comunicaciones del congreso o articulos relacionados con autores/as de la Universidad de Cantabria

 Autoría: Mirapeix J., Cobo A., García-Allende P., Conde O., Lopez-Higuera J.,

 Congreso: Optical Sensing and Detection (2010 : Bruselas)

Editorial: SPIE Society of Photo-Optical Instrumentation Engineers

 Fecha de publicación: 13/05/2010

Nº de páginas: 8

Tipo de publicación: Comunicación a Congreso

 DOI: 10.1117/12.854684

ISSN: 0277-786X,1996-756X

 Proyecto español: TEC2007-67987-C02-01

Url de la publicación: https://doi.org/10.1117/12.854684