Estamos realizando la búsqueda. Por favor, espere...
1551
37
173
26083
4132
2532
334
Abstract: This paper analyses the failure of three bolts used in the structural connections of a number of steel towers located in northern Europe. The analysis comprises optical and scanning electron microscopy, microstructural and hardness analysis, mechanical testing and structural integrity assessments. The three bolts present very similar failure processes, with a circumferential external crack that led to the final failure. The morphology of the crack propagation is typical of Hydrogen-Induced Stress Corrosion Cracking (HISCC), with mixed intergranular-transgranular micromechanisms, tearing processes and secondary cracking. The cracks then grew subcritically until they reached their critical size. Quench cracking or fatigue processes have been ruled out.
Fuente: Metals 2016, 6 (7), 163
Editorial: MDPI AG
Fecha de publicación: 13/07/2016
Nº de páginas: 14
Tipo de publicación: Artículo de Revista
DOI: 10.3390/met6070163
ISSN: 2075-4701
Consultar en UCrea Leer publicación
JOSE ALBERTO ALVAREZ LASO
ROBERTO LACALLE CALDERON
BORJA ARROYO MARTINEZ
SERGIO CICERO GONZALEZ
FEDERICO GUTIERREZ-SOLANA SALCEDO
Volver