A stochastic methodology for the identification of maximum expected fire scenarios in nuclear power plant compartments

Abstract: Fire safety in nuclear power plants is a critical aspect of ensuring their safe operation. The NFPA 805 framework establishes a performance-based, risk-informed methodology that enables the assessment of fire protection measures to be evaluated through computational modelling. This methodology requires the identification of the Maximum Expected Fire Scenarios (MEFS) for each fire area under analysis. However, defining MEFS is complex, since fire development in an enclosure depends on many interacting parameters that may either intensify or mitigate its effects. This study proposes a stochastic methodology for MEFS identification on a representative nuclear power plant scenario. The methodology generates a large number of stochastic fire scenarios using a zone model, such as CFAST, in which key parameters are modified for each simulation: ignition source type, reactive properties and location; thermal properties of combustible materials; and enclosure ventilation conditions. These stochastic simulations are then processed based on the specific failure criterion of the scenario, selecting the most critical fire scenarios for the analysed area. The most critical scenarios are subsequently evaluated with a CFD model, such as Fire Dynamics Simulator (FDS), providing higher fidelity characterisation with quantified uncertainty. The methodology has been applied to a case study based on a multi-compartment geometry derived from the OECD PRISME programme, enhanced with electrical cabinets and cable trays representative of a typical nuclear power plant installation. Two failure criteria are analysed, habitability conditions and redundant cable trays failure. Results show that the methodology successfully identifies the MEFS for each failure criterion. Under the habitability criterion, the critical scenario reaches the critical hot gas layer temperature (95 º C) at 71.8 s in the FDS simulation. Under the thermal damage criterion, both redundant cable trays exceed 300 º C, with failure times of 417.3 s and 393.5 s respectively. These findings demonstrate the practical utility of the proposed approach for fire safety analysis in nuclear facilities.

 Autoría: González-Alvear M., Lázaro M., Alvear D., Jiménez M.A., Morgado E., Lázaro D.,

 Fuente: Applications in Energy and Combustion Science, 2026, 28, 100559

 Editorial: Elsevier

 Fecha de publicación: 01/12/2026

 Nº de páginas: 11

 Tipo de publicación: Artículo de Revista

 DOI: 10.1016/j.jaecs.2026.100559

 ISSN: 2666-352X

 Proyecto español: PID2023-150202OB-I00

 Url de la publicación: https://www.10.1016/j.jaecs.2026.100559

Autoría

MARIA GONZALEZ ALVEAR

JIMÉNEZ GARCÍA, MIGUEL ÁNGEL

MORGADO CAÑADA, EUGENIA