Buscar

Estamos realizando la búsqueda. Por favor, espere...

Detalle_Publicacion

Universal Digital Controller for Boost CCM Power Factor Correction Stages Based on Current Rebuilding Concept

Abstract: Continuous conduction mode power factor correction (PFC) without input current measurement is a step forward with respect to previously proposed PFC digital controllers. Inductor volt-second (vsL) measurement in each switching period enables digital estimation of the input current; however, an accurate compensation of the small errors in the measured vsL is required for the estimation to match the actual current. Otherwise, they are accumulated every switching period over the half-line cycle, leading to an appreciable current distortion. A vsL estimation method is proposed, measuring the input (vg) and output voltage (vo). Discontinuous conduction mode (DCM) occurs near input line zero crossings and is detected by measuring the drain-to-source MOSFET voltage vds. Parasitic elements cause a small difference between the estimated voltage across the inductor based on input and output voltage measurements and the actual one, which must be taken into account to estimate the input current in the proposed sensorless PFC digital controller. This paper analyzes the current estimation error caused by errors in the ON-time estimation, voltage measurements, and the parasitic elements. A new digital feedback control with high resolution is also proposed. It cancels the difference between DCM operation time of the real input current, (TDCMg) and the estimated DCM time (TDCMreb). Therefore, the current estimation is calibrated using digital signals during operation in DCM. A fast feedforward coarse time error compensation is carried out with the measured delay of the drive signal, and a fine compensation is achieved with a feedback loop that matches the estimated and real DCM time. The digital controller can be used in universal applications due to the ability of the DCM time feedback loop to autotune based on the operation conditions (power level, input voltage, output v- ltage...), which improves the operation range in comparison with previous solutions. Experimental results are shown for a 1-kW boost PFC converter over a wide power and voltage range.

 Autoría: Lopez V., Azcondo F., De Castro A., Zane R.,

 Fuente: IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 29, NO. 7, JULY 2014

Editorial: Institute of Electrical and Electronics Engineers Inc.

 Año de publicación: 2014

Nº de páginas: 12

Tipo de publicación: Artículo de Revista

 DOI: 10.1109/TPEL.2013.2280077

ISSN: 0885-8993,1941-0107

Url de la publicación: http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6588592

Autoría

VICTOR MANUEL LOPEZ MARTIN

CASTRO, ÁNGEL DE

REGAN ZANE