Abstract: This paper presents the failure analysis of a cast iron pipe during the pressure test performed once it was already installed and before entering in service. The pipe had previously passed an in-plant pressure test. In order to determine the causes of the failure, visual inspection together with mechanical, chemical and microstructural analysis of the material has been performed. It has been derived that the pipe section that failed during the pressure test had previously suffered mechanical damage during its transportation or installation. Moreover, it has been demonstrated that the material has a very brittle behaviour, with excessive hardness and poor tensile strength and elongation to rupture, and also presents a deficient microstructure in the outer layer of the pipe thickness. This, together with the presence of pre-existing defects caused by the mechanical damage, has produced the final failure of the pipe. Finally, a fracture assessment has been performed in order to estimate the size of the initial pre-existing defects.
Autoría: Lacalle R., Cicero S., Madrazo V., Cicero R., Álvarez J.A.,
Fuente: Engineering Failure Analysis Volume 31, July 2013, Pages 168-178
Editorial: Elsevier BV
Fecha de publicación: 01/07/2013
Nº de páginas: 11
Tipo de publicación: Artículo de Revista
DOI: 10.1016/j.engfailanal.2013.01.027
ISSN: 1350-6307,1873-1961
Url de la publicación: https://doi.org/10.1016/j.engfailanal.2013.01.027
SCOPUS
Citas
Google Scholar
Métricas
Leer publicación
ROBERTO LACALLE CALDERON
SERGIO CICERO GONZALEZ
VIRGINIA MADRAZO ACEBES
ROMAN CICERO GONZALEZ
JOSE ALBERTO ALVAREZ LASO
Volver