Search

Searching. Please wait…

Detalle_Publicacion

Field winding fault diagnosis in DC motors during manufacturing using thermal monitoring

Abstract: Quality assessment during DC motor manufacturing should involve quality controls designed to detect various fault conditions associated with the components included in the machine. Some defects, however, can be produced by the automatic manufacturing process during the assembly of the individual components. Inter-turn short-circuits, turn to earth short-circuits and open winding, among other fault conditions, can result from the field poles manufacturing and insertion inside the stator. The main problem with these kinds of faults is that though the motor is likely to be operational, there is a high probability of motor breakdown in the near future. In this paper, the above fault conditions are analyzed and a thermal model and an infrared monitoring test method for manufacturing quality control is proposed.

Other conference communications or articles related to authors from the University of Cantabria

 Authorship: Manana M., Arroyo A., Ortiz A., Renedo C., Perez S., Delgado F.,

 Congress: International Conference on Renewable Energies and Power Quality: ICREPQ (2011 : Las Palmas de Gran Canaria)

 Publisher: Elsevier Ltd

 Publication date: 01/04/2011

 No. of pages: 6

 Publication type: Conference object

 DOI: 10.1016/j.applthermaleng.2010.11.023

 ISSN: 1359-4311,1873-5606

 Publication Url: https://doi.org/10.1016/j.applthermaleng.2010.11.023